1.Dilute and add sample to Standard: set 10 Standard wells on the ELISA plates coated, add Standard 100μl to the first and the second well, then add Standard dilution 50μl to the first and the second well, mix; take out 100μl form the first and the second well then add it to the third and the forth well separately. then add Standard dilution 50μl to the third and the forth well ,mix ; then take out 50μl from the third and the forth well discard, add 50μl to the fifth and the sixth well ,then add Standard dilution 50μl to the fifth and the sixth well, mix ; take out 50μl from the fifth and the sixth well and add to the seventh and the eighth well, then add Standard dilution 50μl to the seventh and the eighth well ,mix ; take out 50μl from the seventh and the eighth well and add to the ninth and the tenth well, add Standard dilution 50μl to the ninth and the tenth well, mix , take out 50μl from the ninth and the tenth well discard(add Sample 50μl to each well after Diluting ,(density: 120ng/L,80ng/L ,40ng/L,20ng/L,10ng/L)
2.add sample:Set blank wells separately (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40μl to testing sample well, then add testing sample 10μl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.
3.Incubate: After closing plate with Closure plate membrane ,incubate for 30 min at 37℃.
4.Configurate liquid: 30-fold (or 20-fold)wash solution diluted 30-fold (or 20-fold) with distilled water and reserve.
5.washing:Uncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.
6.add enzyme:Add HRP-Conjugate reagent 50μl to each well, except blank well.
7.incubate:Operation with 3.
8.washing:Operation with 5.
9.color:Add Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37℃
10.Stop the reaction:Add Stop Solution50μl to each well, Stop the reaction(the blue color change to yellow color).
11.assay:take blank well as zero , Read absorbance at 450nm after Adding Stop Solution and within 15min.
供應法國佳德瑪便攜式激光甲烷檢測儀INSPECTRA®LASER
INSPECTRA®LASER采用了激光光譜學技術,是一款高性能的天然氣泄漏探測儀。該設備具有ATEX認證,符合關于在爆炸區域使用的標準,可檢測地下網管中的天然氣泄漏并能精確定位泄漏點.
測量原理
激光光譜分析原理。內置一個激光二極管,發射的激光束波長與甲烷的最大吸收波長相等。如遇甲烷分子,部分激光將被甲烷分子吸收,通過測量吸收率即可知道甲烷的濃度。
特點:內置泵吸式采樣系統,測量精度高,系統穩定激光光譜分析法對甲烷具有高度選擇性,對其他各種烴類氣體和化學制品、水蒸氣等不敏感;
測量精度:1PPM
物理測量法,無化學反應,不改變樣氣的特性;
激光檢測速度快,對氣體流量變化不敏感;
不帶有氫氣燃燒氣(FID技術采用),使用更安全;
多通道分析,使得測量范圍更大,同時還能保證精度。(PPM,LEL,VOL);
大屏幕帶背光LCD,兩行大字體顯示,清晰易讀;
兩級采樣泵速,適合快速步行巡檢和微小泄漏的探測;
開機自檢,顯示電池電量和吸氣泵狀態,還具有信息對話窗口;
可選擇不同測量模式:絕對濃度和相對濃度;
外殼設計堅固,防水防塵性能好,
后期維護簡單,使用壽命長。
技術參數
測量原理 激光光譜分析原理
三種測量量程 0~10000ppm;0~100%LEL; 0~100%VOL
精度 ±10%;起測值為1ppm
兩級泵速 不帶采樣桿 T10 2秒; T90 4.5秒
帶采樣桿 T10<3.5秒;T90 6秒
兩種采樣速度35升/小時或70升/小時
供電 可充電電池組:3×1.3VNiCd電池
堿性電池 3節1號1.5V堿性電池(符合ATEX標準要求)
自主運行時間20℃時,充電電池,大于8小時
告警 聲、光警告。可選擇不同的告警等級
尺寸 263mm×113mm×141mm
重量 帶電池重2.7kg
使用環境 溫度 -20℃~ +40℃;濕度 5% ~ 90%
保護等級 IP54
符合標準 CE標志
94/9/CE(1994)ATEX防爆認證指令89/336/CE CEM(1989):電磁兼容指令
歐洲標準(用于爆炸環境中的設備)EN 60079-0, EN 60079-11
計量標準EN 60079-1(2000), EN 61779-4(2001), EN 61779-5(2001) EN 60825(1993)
標準配置1) 一臺Inspectra® Laser 主機2) 一根可伸縮采樣桿3) 一套防水和防塵過濾器4) 一個230VAC的充電器5) 一條主機背帶6) 一個儀器箱7) 說明書
使用范圍•天然氣管網巡檢•檢測和定位天然氣泄漏 對甲烷化裝置進行監測•對天然氣生產平臺及天然氣壓縮廠房中甲烷的暫時性泄漏進行監測
爆炸環境中可安全使用 建筑物內外可使用,通過ATEX認證
選配:手推車可選配手推車采樣裝置,只需將軟管連接到檢測儀上即可將該配件裝配好,用于直接從地面采樣,避免泄漏氣體流失或在空氣中稀釋的風險。
擴展功能(步行巡檢平臺系統)
能與電腦連接,配合GPS定位系統和NGS操作軟件,實現可記錄泄漏數據的步行巡檢,同時自動生成報告。NGS軟件能直觀動態地顯示泄漏點位置和操作者所在位置,配合GPS坐標,使得巡檢結果更具有追溯性。
該系統組成
•一個GPS接收裝置•一條USB電纜,連接Inspectra與電腦•一臺筆記本電腦,用于信息處理•GAZOMAT研發的NGS 多語言軟件
便攜式激光甲烷檢測儀,手推車燃氣檢測儀,手推車天然氣檢測儀,手推車燃氣泄檢測儀,天然氣燃氣爆炸下限檢測儀,多功能氣體泄漏檢測儀,手推車燃氣泄漏檢測儀,路面燃氣巡檢儀,燃氣泄漏檢測儀,天然氣泄漏檢測儀,燃氣檢測乙烷分析儀,相關儀,聽漏儀,管線定位儀,燃氣泄漏檢測儀,管道內窺鏡,激光甲烷遙測儀,激光甲烷遙距檢測儀,天然氣泄漏檢測,手推車燃氣檢漏儀,排水管道檢測儀,供水管道泄漏檢測設備,電纜故障測試儀,管道泄漏檢測,激光甲烷遙測檢測儀,激光甲烷遙距檢測儀,燃氣管道泄漏檢測,燃氣檢測車,燃氣手推車檢測,防腐層檢測儀,管線探測,管線普查,管線物探,管線定位,電纜檢測,電纜故障檢測檢測儀,耐壓測試儀,防腐檢測,埋地管道外防腐層檢測儀,管道檢測,非開挖導向,電纜燒弧儀,地質雷達,清污車,清污設備,管道探測,在線檢測,內窺檢測,管道疏通,測漏儀,管道機器人,管道內窺鏡,測漏,燃氣檢測儀,乙烷辨識儀,甲烷色譜分析儀,多探頭相關儀,管道內窺,切管機,高壓測試儀,電纜測試車,管道檢測,檢漏儀,電纜故障定位,電纜測試設備,爬行器,檢測儀,應急檢漏,漏水檢測工程,路面鉆孔機,路面打孔機,路面開孔機
213/224nm深紫外調Q激光器
IMPRESS系列是一款高重頻二極管泵浦調Q深紫外激光器,可以輸出波長213nm和224nm,TEMoo模激光器可以作為光學度量和微處理,比如:半導體加工和顯示修復。其短波長等屬性也使得這款激光器可以應用于光學直寫。該激光器可提供<9ns的超短脈沖,光束質量M2<1.6。通過RS232可實現電腦控制,也兼容其他觸發控制。
產品特點:
● 深紫外超短脈沖
● 二極管泵浦
● 槽安裝激光二極管
● 光學特性好
● 高脈沖功率
● 價格低
● 綠色光子學
產品應用:
● 光纖布拉格光柵制作
● 波長敏感處理
● 立體光刻
● 顯示修復
● 微處理
● 半導體觀察
● 替代了Ar-Ion的倍頻激光器
● 激光激發測量
頂尖科儀(中國)股份有限公司是一家專業代理和經銷國際品牌的激光器、光譜儀器、光學、光電子、光機械和光纖通訊產品的高科技貿易和技術服務公司。公司代理 和經銷產品廣泛,涉及光電子、光通訊、激光、光學、物理、電子和生物等領域,可廣泛應用于教學、科研、產品開發及規模生產。頂尖科儀以強大的生產商陣容、 廣泛的產品和強大的技術支持為支撐,致力于開拓中國市場,為中國廣大的科研和工業客戶提供國際一流的產品和服務。
頂尖web:http://www.psci.cn/
雷疇web:http://www.zcnsci.cn/
雷疇淘寶web:https://shop151914141.taobao.com/ 地址: 中國.浙江省杭州市江干區錢江新城民心路100號萬銀國際大廈2404室
電話:
E-mail:sales@psci.cn
微信號:pscicc
中山市三和機電有限公司是高技術型現代化液壓生產企業,專業生產膠管扣壓機、非標液壓系統及非標準液壓缸。多年從事氣動元件、液壓元件、機電一體化設備配件的專業性公司,是中山地區的SMC、SANWO、YUHUA、DINGLI 、FUSTAR的一級代理。
第二節:產品特點
1.中和靜電迅速.
2. 工作性能穩定安全.
3. 安裝簡單方便.
4. 風槍風咀有良好的接地保護.
第三節:技術參數
| |
| |
| |
| |
*離子平衡電壓和靜電消除時間符合ESD標準,靜電消除時間是從測試電壓為5000v~500v測得.
*測試儀器使用ME269A靜電綜合測試儀.
*測試數據會因周圍空氣的溫濕變化而有差異.
第四節:安全
4.1 安裝操作前須讀操作說明書.
4.2 操作前必需接地.
4.3 不可在有可燃性氣體和粉塵環境下使用.
4.4 保持風槍氣源干燥,無油和積灰.
4.5 不得擅自進行修理和安裝.
第五節:安裝及操作
斯萊德離子風槍風咀要配備SL-007/A高壓發生器一起使用。將風槍風咀連接線末端插入高壓發生器高壓輸出插孔,順時針旋轉到頭,然后將風槍風咀連線的接地線連接到高壓發生器外側的接地柱上,并確認接地良好后,將高壓發生器的插頭插入帶有接地線的插座上(注意高壓發生器的使用電壓),風槍風咀街上壓縮氣,打開高壓發生器的電源即可工作。
離子風槍風咀在使用一段時間后,離子針周圍會發生積塵,請定期進行清潔,清潔時要關斷電源.
1. 電源的安裝
2. 風槍風咀的安裝:
第六節:產品保修與服務
斯萊德嚴格遵守:產品質量,信譽,客戶至上的宗旨,對斯萊德產品實行以下:
1.保用期
凡本公司出售的產品保用期為一年,自出售日起一年內因產品自身機件、材料及工藝問題造成的質量問題,本公司免費修理。
2.保用期后的服務
凡本公司出售的產品保用期過后仍負責對產品的免人工費修理,以保護客戶的利益。
*以上產品技術參數解釋權屬斯萊德靜電消除設備制造商所有.
淋雨試驗箱技術參數:
工作室尺寸:1000*1000*1000
噴水環半徑:375或500(mm)
水管直徑:¢16mm
噴水孔徑:¢0.4mm
孔徑間距:50mm
擺管擺幅:90°,180°,270°
直角轉臂:360°旋轉
轉盤:配有適中的圓形轉盤(放樣品用)轉速可調
調速器:進口變頻調速器
內外材料:SUS304不銹鋼板
BAD54-G防爆防腐防塵防爆燈,不銹鋼250w防爆燈,E40不銹鋼防爆燈外殼,不銹鋼防爆燈供應電話,不銹鋼防爆燈最新單價,不銹鋼防爆燈參數,250w不銹鋼防爆燈外殼。不同安裝方式不銹鋼防爆燈。
適用范圍:
◆ 適用于性氣體環境2區;◆ 適用于ⅡA、ⅡB、ⅡC級性氣體環境;◆ 適用于溫度組別為T1~T2的性氣體環境;◆ 可配裝白熾燈、自鎮汞燈;◆ 座式安裝時,可用作局部區域投光照明;◆ 適用于石油采煉、儲存、化工、醫藥、設施等性危險環境
BGL-20'0'G不銹鋼防爆燈:
產品名稱 | 簡介 |
◆ 適用于性氣體環境2區;◆ 適用于ⅡA、ⅡB、ⅡC級性氣體環境;◆ 適用于溫度組別為T1~T2的性氣體環境;◆ 可配裝白熾燈、自鎮汞燈;◆ 座式安裝時,可用作局部區域投光照明;◆ 適用于石油采煉、儲存、化工、醫藥、設施等性危險環境。
選型指南 |
2、建議選用亞明、飛利浦品牌光源;
產品特點 |
技術參數 |
執行標準:GB 3836.1、GB 3836.3、IEC60079
防爆標志:Exe ⅡT2
額定電壓:AC 220V
燈座規格:E27 E40
配裝光源:B200、Z160 B300、Z250
可配光源最大長度:265mm
防護等級:IP65
防腐等級:WF2
引入口規格:G3/4"